Oxygen Diffusion Silencer

1.Manufacture standard:GB 12348-1990.
2.Inspection standard:GB/T 14623-1993.
3.Silencer absorbance:30~45dB.
4.Flange standard:HG,GB,HGJ,JB,ANSI,,DIN,BS,NF.
5.Air displacement:1500~10800m3/h.
6.Material:A3,304,304L,316,316L.
7.Sealing gasket:NBR,PTFE,Metal,Graphite.
8.Operating temprature:0℃~540℃.


Fundamental dimensions of Oxygen Diffusion Silencer:

DN /mm

P /Pa

V /(m3/h)

D /mm

L /mm

80

2.0 ≤P ≤3.0

1500~3000

450

2000

100

2.0 ≤P ≤3.0

3000~6000

500

2000

125

2.0 ≤P ≤3.0

6000~10000

550

2000

150

≤3.0

10000~14000

700

2500

200

2.0 ≤P ≤3.0

14000~24000

800

2500

80

≤1.0

600~1100

400

2000

100

≤1.0

1100~1700

450

2000

150

≤1.0

2300~3800

500

2000

200

≤1.0

4200~6900

550

2500

250

≤1.0

6900~10800

650

2500

Drawing of Oxygen Diffusion Silencer: