FXT02-3 Heat Insulation Finish
[Search Related Products]
FXT02-3 Heat Insulation Finish(use for different kinds of air storage tank ektexine)
Characteristics: paint film firm、abrasion resistance、good reflection effects to sun heat emission、good construction property、good color and gloss retention.
Uses: special infrared ray reflection paint, mainly use for steel material、air storage tank ektexine anticorrosion, as a use of finish.
Technical target��
Mixing ratio: Host crystal/Firming agent=7/1(by weight)
Standard film thickness: Dry: 30μm/coat
Academic spreading rate: 0.10kg/ �O/30μm
Solid contents: 63%
Humidity requirement: below 85%
Drying time & Coating interval
|
Temperature �─罍� |
5 |
10 |
20 |
30 |
|
Dry to touch��hrs�� |
4 |
2 |
1.5 |
1 |
|
Dry semi-hard��hrs�� |
36 |
24 |
12 |
8 |
|
Min. interval��hrs�� |
36 |
24 |
12 |
8 |
Substrate treatment��Intermediate paint surface should be clean and dry, no feculence
Matching ��
Applicable under coatings: Heat Insulation Intermediate Paint
Application on Different Kinds of Air Storage Tank Ektexine: